Stormwater Systems

RECHARGER® 360HD

36 in / 914 mm
MODEL # 360HD

The Recharger® 360HD is a 36″ (914 mm) tall, high capacity chamber. Typically when using this model, fewer chambers are required resulting in less labor and a smaller installation area. The Recharger® 360HD has the side portal internal manifold feature. HVLV® FC-48 Feed Connectors are inserted into the side portals to create the internal manifold.
Contractors are able to hand place the units on-site, unlike larger, more cumbersome competitive products.

Meets ASTM F3430, F2418 and F2787 standards.

CULTEC StormGenie Design Tool

Design your stormwater project using our StormGenie Design Tool.
Generate accurate, project-specific CAD drawings and reports.

ADDITIONAL BENEFITS
Value engineered design for maximum cost savings.
Adheres to AASHTO LRFD Design Standards.
55% more storage per foot over the leading 30″ high competitor chamber.
8.6% more storage per foot over 42″ HDPE pipe.

Length

4.17 ft1.27 m

Width

60 in1525 mm

Height

36 in914 mm

Installed Length

3.67 ft1.12 m

Length Adjustment per Row – with two end caps installed

2.50 ft0.76 m

Length Adjustment per Row – when not using end caps

.50 ft0.15 m

Chamber StorageThese values are based on the installed length of the chamber. See specifications for installed length.

10.00 ft³/ft36.66 ft³/unit.929 m³/m1.038 m³/unit

Min. Installed StorageThese values are based on the installed length of the chamber. See specifications for installed length.

15.199 ft³/ft55.73 ft³/unit1.412 m³/m1.58 m³/unit

Min. Area RequiredThis is the area of the installed length of the chamber multiplied by the center-to-center spacing.

21.08 ft²1.96 m²

Min. Center-to-Center Spacing

5.75 ft1.75 m

Max. Allowable Cover

3.66 m12 ft

Max. Allowable O.D. in Side PortalO.D. = outside dimension of pipe

11.5 in292 mm

Compatible Feed Connector

HVLV FC-48 Feed Connector

Compatible End Cap

Recharger 360HD End Cap