Septic Systems

Contactor & Recharger Septic Chambers

The CULTEC Contactor and Recharger chambers replace conventional stormwater management systems such as ponds, swales, pipe and stone trenches or beds, or concrete structures. The chambers may be used for drywells. They may be installed in trench or bed configurations according to site restrictions or client preference. Contact area is maximized by the fully open bottoms and perforated sidewalls. The chambers are typically installed subsurface beneath parking areas to capitalize on use of space, however, they may also be placed in grassy areas.

show more

CULTEC offers the largest variety of chamber sizes and therefore is able to accommodate almost any site parameter whether it is big or small.

Sizes range from 8.5” to 48” tall. Chamber storage capacities range from 0.819 ft³/ft to 17.66 ft³/ft.

System benefits include:

  • Maximum use of land area
  • Ability to recharge water on-site
  • Lightweight
  • Less heavy equipment required
  • Overlapping rib connection is fast and easy to install
  • Repeating support panel adds to strength of installation
  • Chemically resistant
  • Sub-surface installation cuts down on insurance liabilities and potential breeding grounds for infectious mosquitoes
  • Ability to stack units for trouble-free stockpiling on jobsite and shipping
CULTEC’s Recharger series are higher profile, larger capacity chambers. Typical CULTEC stormwater systems are designed by using the largest chamber that meets the site’s depth constraint. By doing so you reduce the number of chambers and land area required. You maximize storage volume at the given workable elevations.

CULTEC’s low profile Contactor series can accommodate systems with high water tables or other depth restraints. The lower profile units may also be used when a larger infiltrative surface area is required by design

CULTEC chambers may be installed in multiple layers to accommodate tight site constraints. The Contactor Chamber series consists of lower profile, lower capacity chambers and are typically used for installations with depth restrictions or when a larger infiltrative area is required. Conventional manifolds must be used with all models in this series except the Contactor 100HD. The Contactor 100HD has the side portal internal manifold option.

The Recharger series consists of higher profile, higher capacity chambers. When using this series, less chambers are required resulting in less labor and a smaller installation area.
Heavy Duty (HD) versions must be used for traffic applications.

Our most popular and cost-effective models used for stormwater are the 100HD, 150XLHD, 280HD, 330XLHD, & 902HD. Other models are available but not listed. Please contact our Technical Department at 203-775-4416 if the models listed below do not fit your parameters.

show less

Model # Model Name Length Installed Length Width Height Invert Height

C-4

Contactor® Field Drain™ C-4

8.50 ft2.59 m

8.00 ft2.44 m

48 in1219 mm

8.50 in216 mm

3 in76 mm

EZ-24

Contactor® EZ-24

8.50 ft2.59 m

8.00 ft2.44 m

16 in407 mm

12.00 in305 mm

6 in152 mm

100

Contactor® 100

8.00 ft2.44 m

7.40 ft2.26 m

36 in914 mm

12.50 in318 mm

6 in152 mm

100HD

Contactor® 100HD

8.00 ft2.44 m

7.50 ft2.29 m

36 in914 mm

12.50 in318 mm

6 in152 mm

150XLHD

Recharger® 150XLHD

11 ft3.35 m

10.25 ft3.12 m

33 in838 mm

18.50 in470 mm

12 in305 mm

180HD

Recharger® 180HD

7.33 ft2.23 m

6.33 ft1.93 m

36 in914 mm

20.50 in521 mm

14 in356 mm

202

Contactor® 202

8.33 ft2.54 m

7.00 ft2.13 m

24 in610 mm

24 in610 mm

17 in432 mm

280HD

Recharger® 280HD

8.00 ft2.44 m

7.00 ft2.13 m

47 in1194 mm

26.50 in673 mm

20.5 in521 mm

330XLHD

Recharger® 330XLHD

8.50 ft2.59 m

7.00 ft2.13 m

52 in1321 mm

30.50 in775 mm

24 in610 mm

Request Information