Stormwater Systems
RECHARGER® 150XLHD
18.5 in / 470 mm
MODEL #150XLHD
The Recharger® 150XLHD is an 18.5″ (470 mm) tall, lower profile chamber and is typically used for installations with depth restrictions or when a larger infiltrative area is required. The Recharger 150XLHD has the side portal internal manifold feature. There are two side portals on each side of the chamber. HVLV FC-24 Feed Connectors are inserted into the side portals to create the internal manifold.
show more
Available models:
- Recharger 150XLRHD Heavy Duty Stand Alone Unit
- Recharger 150XLSHD Heavy Duty Starter Unit
- Recharger 150XLIHD Heavy Duty Intermediate Unit
- Recharger 150XLEHD Heavy Duty End Unit
CULTEC StormGenie Design Tool
Design your stormwater project using our StormGenie Design Tool.
Generate accurate, project-specific CAD drawings and reports.
show less
Length | 11 ft3.35 m |
Width | 33 in838 mm |
Height | 18.50 in470 mm |
Installed Length | 10.25 ft3.12 m |
Length Adjustment per Run | 0.75 ft0.23 m |
Chamber StorageThese values are based on the installed length of the chamber. See specifications for installed length. | 2.650 ft³/ft27.16 ft³/unit203 gal0.25 m³/m0.77 m³/unit769.12 L |
Min. Installed StorageThese values are based on the installed length of the chamber. See specifications for installed length. | 4.89 ft³/ft50.17 ft³/unit375 gal0.45 m³/m1.42 m³/unit1420.46 L |
Min. Area Required per UnitThis is the area of the installed length of the chamber multiplied by the center-to-center spacing. | 33.31 ft²3.09 m² |
Min. Center-to-Center Spacing (Design Unit Width) | 3.25 ft0.99 m |
Max. Allowable Cover | 3.66 m12 ft |
Max. Inlet Opening in End Wall | 12 in300 mm |
Max. Allowable O.D. in Side PortalO.D. = outside dimension of pipe | 10.25 in260 mm |
Compatible Feed Connector | HVLV FC-24 Feed Connector |