Stormwater Systems

CULTEC No. 4800 Woven Geotextile

CULTEC No. 4800™ Woven Geotextile is designed to provide an economical solution to prevent scouring at inlets and beneath the CULTEC internal manifold feature. It may also utilized below the chambers of the CULTEC Separator Row as a barrier to prevent soil/contaminate intrusion and allow maintenace of the water quality system.

show more

CULTEC No. 4800 is a woven geotextile made of 100% high-tenacity polypropylene yarns. CULTEC No. 4800 resists ultraviolet and biological deterioration, rotting, naturally encountered basics and acids. Polypropylene is stable within a pH range of 2 to 13. US 4800 meets the following M.A.R.V. values except where noted.

show less

Appearance

Black

Tensile Strength (ASTM-D-4632)

550 x 550 lbs2,448 x 2,448 N

Elongation @ Break (ASTM-D-4632)

20 x 20%

Wide Width Tensile (ASTM-D-4595)

5,070 x 5,070 lbs/ft74 x 74 kN/m

Wide Width Tensile @ 2% Strain (ASTM-D-4595)

960 x 1,096 lbs/ft14 x 16 kN/m

Wide Width Tensile @ 5% Strain (ASTM-D-4595)

2,740 x 2,740 lbs/ft40 x 40 kN/m

Wide Width Tensile @10% Strain (ASTM-D-4595)

4,800 x 4,800 lbs/ft70 x 70 kN/m

CBR Puncture (ASTM-D-6241)

1,700 lbs7,560 N

Trapezoidal Tear (ASTM-D-4533)

180 x 180 lbs801 x 801 N

Apparent Opening Size (ASTM-D-4751)

40 US Sieve0.425 mm

Permittivity (ASTM-D-4491)

0.15 Sec-1

Water Flow Rate (ASTM-D-4491)

11.5 g/min/sf470 l/min/sm

UV Resistance @ 500 Hours (ASTM-D-4355)

80%

Request Information